Publication 2755-838

Message Buffer

Specifies the number of messages held in the message buffer and the
limit at which a warning occurs if the buffer size is exceeded. Use
the message buffer when the host device cannot handle high data
rates from the Reader.

Note: Do not set the buffer size >1 when data sent to a host device
must be coordinated with the I/O on a Reader.

Select

To

Enable Warning

Enable the buffer full warning.

Warning At

Specify the warning limit for the buffer (default is 2). When the
limit is met or exceeded, a warning is provided.

Buffer Size

Specify the maximum number of messages the message buffer
can store (default is 5). Buffer is always active whether or not
warning is enabled / disabled.

Device

Select the Reader that will provide the buffer
warning.

Output

Select the output to energize when the buffer limit is reached.

Connection

Select the communications port that can connect to the host. Select
RS-232, RS-422 or RS-485.

Enable Pass-Through to DeviceNet

Allows data from the serial port to pass through to a DeviceNet
network. Page 10–15 shows an example of how to use this feature.