Downloading firmware – Rockwell Automation 2755 AdaptaScan Software User Manual
Page 56
4–9
Getting Started
Publication 2755-838
If the Reader is being operated for the first time (out of the box), you
must download operating firmware.
The Reader is shipped with a default DeviceNet address of 63.
To download operating firmware to the Reader:
1. From the Communications menu, select Go-Online.
The reader will be detected (if properly connected) and displayed
in the project window.
Note: The Query dialog may be displayed when you go on-line
(depending on your preference settings). Refer to page 2–19.
Note Address
2. From the Project window, highlight the Reader name and then
click the Firmware button.
The Open dialog is displayed allowing you to enter or browse to
the firmware file you want to download.
SNEXaaaa.ini
Select .ini
Firmware File
aaaa = Version Number
Downloading Firmware