Communications setup – Rockwell Automation 2755 AdaptaScan Software User Manual

Page 54

Advertising
background image

4–7

Getting Started

Publication 2755-838

The Reader configuration port is set for 9600 Baud and cannot be
changed. This port is set by default to communicate with the first
port that is available on your computer.

If your computer is using a different communication port, change the
port by selecting Preferences from the View menu.

To change communication port settings:

1. Select Preferences from the View menu.

The Preferences dialog opens.

2. Select the communications port connected to the Reader.

3. Make sure that Configuration Port connection is selected.

4. Click OK to save changes.

Note: The Reader can also be connected to a Reader through a
DeviceNet network connection. A DeviceNet communications card
and driver software must be installed on your computer. If you are
using DeviceNet Manager Software (Catalog No. 1787-MGR) to
connect to an AdaptaScan Reader in a network, refer to the user
manual (Publication No. 1771-2.29). Select DeviceNet connection
on the Preferences dialog when using a DeviceNet network
connection.

Communications Setup