Rockwell Automation 2755 AdaptaScan Software User Manual

Page 61

Advertising
background image

4–14

Getting Started

Publication 2755-838

Position the Reader:

1. Place the test symbol approximately 12 inches (.3 meter) in front

of the Reader so that the scan beam crosses the symbol.

Test Card

Observe

On Symbol

LED

Make sure symbol
is slightly skewed.

2. Observe the ON Symbol LED on top of the Reader. When the

LED is illuminated, the Reader is scanning an enabled
symbology.

Note: The ON Symbol LED may not light (bar code symbol not
read) if the Reader is not focused correctly or the symbology is
not configured.

Adjust scan line elevation and width:

If the scan line does not completely cross the UPC-A symbol, adjust
the scan line elevation and width.

1. Increase or decrease the scan width and elevation.

2. Click Apply to send the new settings to the Reader, wait for the

changes to take affect.

3. Repeat adjustments until the scan line is crossing all of the

symbol.

Advertising