10–11

Publication 2755-838

Field Delimiter

Specifies a 3-digit decimal equivalent of an ASCII character to
indicate the start and end of bar code label data. When Disable is
selected, delimiters are not inserted into the message data.

Field Data

When selected, bar code field data is included in the message.

Scan Count

When selected, sends the number of scans decoded within the
decoder trigger period (up to 99).

Counter

Select:

To:

Include

Include counter data in each message.

Device

Specify the Reader source of the counter data.

Counter

Specify the counter data (package or match entry) to include in
the message.

Message Destination

Specifies the communications port connector through which bar code
messages are sent.

Select:

To:

DeviceNet

Send messages out through the DeviceNet port. See next
page for additional information.

Serial Port

Send messages out through the RS-232, RS-422, or RS-485
port connectors.

Handshaking

When selected, allows the PLC or SLC to control the transfer of
message data. Refer to DeviceNet messages (next page).

Current Message Size

Displays the message size in bytes as it is configured. Size is
updated as selections are made. Use the message size when setting
up your DeviceNet scanner message addressing (see page 10–13).