Configuring the timer – Rockwell Automation 2755 AdaptaScan Software User Manual

Page 130

Advertising
background image

9–9

Publication 2755-838

The Timer dialog configures the operation of the Reader’s internal
timer. Open this dialog by selecting Timer from the list on the Input
& Output dialog and then clicking the Edit button.

Timer Name

Specifies a unique name for the timer. This name will appear in lists
where a timer trigger can be assigned.

Cyclic Timer

Specifies the length of time that the timer remains on before cycling
off.

Select:

To:

On Time

Enter a value for the length of time the timer remains on before
cycling off. Enter a value between 0 and 32767 milliseconds (0
to 32.767 seconds).

Off Time

Enter a value for the length of time the timer remains off before
cycling on. Enter a value between 0 and 32767 milliseconds (0
to 32.767 seconds).

Configuring the Timer

Or double-click on Timer
to open the dialog.