Installing the reader, Connecting the configuration cable, Power-up sequence – Rockwell Automation 2755 AdaptaScan Software User Manual
Page 52

4–5
Getting Started
Publication 2755-838
Carefully position the Reader on the wiring base. You don’t need to
tighten the screws for this sample application.
Screws
4 Locations
Don’t Tighten Screws
Wiring Base
Insulating
Cover
Use the configuration cable (Catalog No. 2755-NC48 Series B,
2755-NC43 Series A) provided with the AdaptaScan software to
connect the computer’s communication port to the Reader’s
configuration port. If the computer has a 25-pin connector, you need
a 9-to-25 pin adapter.
Configuration
Port Connector
Personal Computer
Configuration Cable
(Catalog No. 2755-NC48 or -NC43)
9-to-25 Pin Adapter
may be required
9 Pin Male
D Connector
4 Pin Female
Circular Connector
Power source required
See Reader user manual
(Publication No. 2755-837)
Apply power to the Reader. On initial powerup, the Reader performs
a series of self-diagnostic tests and LED tests (all LEDs flash).
Refer to table page 3–6 for a description of the LED indicators.
When the Module LED flashes and turns a steady or flashing green,
the powerup sequence is complete. The complete powerup sequence
takes a few seconds.
Installing the Reader
Connecting the
Configuration Cable