Installing the reader, Connecting the configuration cable, Power-up sequence – Rockwell Automation 2755 AdaptaScan Software User Manual

Page 52

Advertising
background image

4–5

Getting Started

Publication 2755-838

Carefully position the Reader on the wiring base. You don’t need to
tighten the screws for this sample application.

Screws
4 Locations
Don’t Tighten Screws

Wiring Base
Insulating
Cover

Use the configuration cable (Catalog No. 2755-NC48 Series B,
2755-NC43 Series A) provided with the AdaptaScan software to
connect the computer’s communication port to the Reader’s
configuration port. If the computer has a 25-pin connector, you need
a 9-to-25 pin adapter.

Configuration

Port Connector

Personal Computer

Configuration Cable
(Catalog No. 2755-NC48 or -NC43)

9-to-25 Pin Adapter

may be required

9 Pin Male

D Connector

4 Pin Female

Circular Connector

Power source required

See Reader user manual

(Publication No. 2755-837)

Apply power to the Reader. On initial powerup, the Reader performs
a series of self-diagnostic tests and LED tests (all LEDs flash).
Refer to table page 3–6 for a description of the LED indicators.
When the Module LED flashes and turns a steady or flashing green,
the powerup sequence is complete. The complete powerup sequence
takes a few seconds.

Installing the Reader

Connecting the
Configuration Cable

Power-up Sequence