Rockwell Automation 2755 AdaptaScan Software User Manual
Page 18

1–8
Installation
Publication 2755-838
Download the Firmware to the Reader
1. Check that Reader is properly connected to your computer (using
configuration cable) and has power applied (refer to page 1–5).
2. Select Preferences from the View menu.
SNEXaaaa.ini
3. Make sure the communications channel is set to Configuration
Port.
4. From the Communications menu, select Go-Online.
The Reader will be detected (if properly connected) and displayed
in the project window.
Note: The Query dialog may be displayed when you go on-line
(depending on your preference settings). Refer to page 2–19.
5. From the Project window (see page 1–6), highlight the Reader
name and then click the Firmware button.
The Open dialog is displayed allowing you to enter or browse to
the firmware file you want to download.
Select .ini
Firmware File
aaaa = Version Number
SNEXaaaa.ini
6. Select the firmware file you want to download and click OK.
The following messages appear as the firmware is downloaded.
Downloading will take several minutes. During this time the
Module LED will flash red.
Resetting. Please Wait . . .
Sending. Please Wait . . .
7. The messages disappear when the download is complete.
You are ready to create a Reader configuration.