Configuring devicenet parameters – Rockwell Automation 2755 AdaptaScan Software User Manual

Page 112

Advertising
background image

8–3

Publication 2755-838

Two dialogs define DeviceNet parameters, one defines the baud rate
of the project, the other defines a Reader address within the project.

Project Dialog

The Project dialog defines the baud rate for all Readers on the same
DeviceNet network. The project name and description fields are
defined on page 2–17. The Project dialog opens whenever you open
a new project or when selecting Edit from the Project menu.

DeviceNet Baud Rate

Select a rate for all Readers defined within the project.

Baud Rate:

Supports maximum cable length of:

125 Kbps

1600 feet (500 meters)

250 Kbps

600 feet (200 meters)

500 Kbps

300 feet (100 meters)

Configuring
DeviceNet Parameters