Rockwell Automation 2755 AdaptaScan Software User Manual
Page 166

11–14
Publication 2755-838
Triggered By
Specifies when the Reader activates an output if a package is
decoded. Items that appear in brackets specify the same trigger
assigned to the specified function. For example, selecting [Decoder]
indicates that packages use the same trigger assigned to the decoding
function.
Highlight the package definition you want to assign a trigger for and:
Select:
To:
Device
Specify the Reader that is the source of the trigger.
Input
Specify the input to provide the timing of a package output.
The following selections are typical trigger inputs.
Select:
To:
Package Detect
Use a package detector as the trigger source.
Timer
Use the internal Reader timer as the trigger source.
ASCII
Command
Use an ASCII command as the trigger source.
Input Timer
Use input timer 1 or 2 as the trigger source.
[Decoder]
Use the decode trigger as the trigger source.
[Match Table]
Use the match table trigger as the trigger source.
[Message]
Use the message trigger as the trigger source.
[Package]
Use the package trigger on another Reader as the trigger
source.