Publication 2755-838

Space Tolerance

The maximum allowed tolerance (percent difference in width)
between the narrowest and widest space elements.

Enter:

To:

Tolerance

Specify the percent difference (in width) between the narrowest
and widest space elements. Enter a value between 5 and 40.
The default of 15 is recommended for most applications.

Space tolerance is calculated as follows;

Widest Space – Narrowest Space

Widest Space + Narrowest Space

3

x 100 = % Space Tolerance

Min Wide to Narrow Bar Ratio

Specifies the minimum ratio of the widest bar to the narrowest bar
within a symbol. Select: No Check, 2, or 3.

Bar Tolerance

Note: The maximum number of bars allowed in a symbol is 12.

The maximum tolerance (percent difference in width) between two
wide bars of a symbol or between two narrow bars of a symbol.
Enter a value between 5 and 40. The default of 15 (15%) is
recommended for most applications.

Bar tolerances are calculated as follows:

Widest Wide Bar – Narrowest Wide Bar

Widest Wide Bar + Narrowest Wide Bar

3

x 100 = % Wide Bar Tolerance

Widest Narrow Bar – Narrowest Narrow Bar

Widest Narrow Bar + Narrowest Narrow Bar

3

x 100 = % Narrow Bar Tolerance