Configuring discrete outputs – Rockwell Automation 2755 AdaptaScan Software User Manual
Page 129
![background image](/manuals/580376/129/background.png)
9–8
Publication 2755-838
The Discrete Output dialog configures the operation of the Reader’s
output module(s). Open this dialog by selecting an output from the
list on the Input & Output dialog and then selecting the Edit button.
Output Name
Specifies a unique name for the output. Enter a name that properly
identifies the output as discrete output 1 or 2 (position in wiring
base).
Output State
Specifies the inactive (untriggered state) of the output module
contacts.
Select:
To Specify:
Normally Open
The module output contacts open in the inactive (untriggered)
state.
Normally Closed
The module output contacts close in the inactive (untriggered)
state.
On Time
Specifies the length of time the output remains active after triggered.
Enter a value in the range of 0 to 32,767 milliseconds (0 to 32.767
seconds). A value of 0 indicates no timing, the output on time tracks
the input trigger.
Configuring Discrete Outputs
☞
Or double-click on an output
to open the dialog.