Triggered By

Specifies the trigger that sends a message to the host. The Reader
sends messages at the end of a trigger or when data is available.

Note: If DeviceNet is selected as the host (page 10–10), messages
are queued until requested by the DeviceNet master (see Message
Flow Control page 10–13). The trigger controls when messages are
placed in the queue.

Select

To

Enable

Enable the message trigger. If not selected, mes-
sages are not sent.

Device

Select the Reader that is the source of the
trigger.

Input

Select the input on the specified device (Reader) to
trigger a message send.

Send at End of Trigger

Send a message at the end of a trigger.

Send When All Fields Are Sa-
tisfied.

Send a message immediately when all of the ex-
pected fields have been decoded or at the end of
the trigger.

Any configured input is available as a message trigger, including:

Select

To

Package Detect

Use the package detect input as the trigger source.

Timer

Use the internal Reader timer as the trigger source.

ASCII
Command

Use an ASCII command as the trigger source.

Input Timer

Use the input timer as the message trigger.

DeviceNet
Inputs 1

!7

Use a DeviceNet input as the message trigger.

[Decoder]

Use the decode trigger as the trigger source.

[Package]

Use the package trigger as the trigger source.

[Match Table]

Use the match table trigger as the trigger source.

[Message]

Use the same message trigger used by another Reader.