Rockwell Automation 2755 AdaptaScan Software User Manual

Page 91

Advertising
background image

6–9

Publication 2755-838

Include Identifier

When selected, the identifier is included as part of the symbol data.

Lengths

Optional data field that specifies the minimum and maximum
number of characters in the symbol. Enter up to 3 specific lengths
for each symbol definition. Symbols that do not have the specified
number of characters are ignored.

For:

Guidelines are:

Code 39

The code length includes the check character but not the start
and stop characters.

Codabar

Code length includes the check character and the start and
stop characters.

Code 128

The code length does not include the check characters or start
and stop characters. Shift characters within the symbol are not
included in the length. The Reader ignores Code 128 FNC2,
FNC3, and FNC4 characters regardless of the CODE 128
FNC1 setting. FNC2, FNC3, FNC4 are also ignored by the
specific length check.

Code 93

The code length does not include the check characters or start
and stop characters. Shift characters within the symbol are not
included in the length.

Discrete 2 of 5

The code length includes the check character but not the start
and stop characters.

I 2 of 5

The code length includes the check character but not the start
and stop characters.

Matrix 2 of 5

The code length includes the check character but not the start
and stop characters.

PharmaCode

The length defines the number of characters in the decoded
symbol. The maximum character length of a 12 bar Pharma-
code symbol is 5.

USPS 2 of 5

Does not have start, stop or check characters. The length is
the number of data characters in the symbol.