Connecting the dl10 slave – Rockwell Automation 2755 AdaptaScan Software User Manual
Page 51
Advertising
![background image](/manuals/580376/51/background.png)
4–4
Getting Started
Publication 2755-838
Use a two conductor shielded cable to connect the DL10 data display
to the RS-232 port of the Reader. The DL10 is optional. If you
don’t have a DL10, you can still view decoded data using the
configuration software monitor function.
Note: The data viewed on the monitor window does not necessarily
correlate with the data sent out of the serial port. The monitor
window displays unformatted data while the serial port data may be
formatted to contain other data such as replacement strings, source
ID, etc.
Tx
GND
Reader Wiring Base
RS-232 Port
Dataliner
Communications Port
Dataliner DL10
Message Display
Connect to 120 VAC
Power Source
Use Belden 8303
or equivalent
Connecting the
DL10 Slave