Configuring an ascii trigger – Rockwell Automation 2755 AdaptaScan Software User Manual

Page 133

Advertising
background image

9–12

Publication 2755-838

The ASCII Command Input dialog configures ASCII commands that
the Reader will interpret as trigger on and trigger off commands.
Open this dialog by selecting ASCII Command 1 or 2 from the list
on the Input & Output dialog and clicking the Edit button.

ASCII Command Name

Specifies a unique name for the trigger commands. This name
appears in lists where an ASCII command trigger can be assigned.

Use Port On

Assigns the ASCII commands to a specific Reader. The ASCII
trigger commands can only be assigned to a single Reader.

ASCII Command

Specifies the ASCII strings that the Reader interprets as a trigger on
or trigger off command.

Select:

To:

Turn On ➀

Enter the ASCII string that the Reader will interpret as a trigger
on command.

Turn Off ➀

Enter the ASCII string that the Reader will interpret as a trigger
off command.

On Time

Enter a value for the length of time the trigger remains on if a
trigger off command is not received. Enter a value between 0
and 32767 milliseconds (0 to 32.767 seconds). A value of 0
disables the timer.

➀ The message header and trailer or message size allow the Reader to separate

ASCII commands from other data.

Configuring an ASCII Trigger