Rockwell Automation 2755 AdaptaScan Software User Manual

Page 132

Advertising
background image

9–11

Publication 2755-838

Timing

Specifies the operation of the Input Timer.

Delay

Specifies delays between the trigger input and the turning on and off
of the input timer.

Select:

To:

On

Enter the delay (in milliseconds) between the trigger input and
when the input timer turns on.

Off

Enter the delay (in milliseconds) between when the trigger
input turns off and when the input timer turns off.

Limits

Specifies minimum and maximum on times for the input timer.

Select:

To:

Minimum

Enter the minimum amount of time (in milliseconds) that the
input timer can be on.

Maximum

Enter the maximum amount of time (in milliseconds) that the
input timer can be on.

Cyclic Operation

Specifies that the input timer turns on and off for set periods after
being triggered. Cyclic operation only occurs while the input trigger
is active.

Select:

To:

Enable

Enable cyclic operation. When not selected, the timer remains
on.

On Time

Enter the period of time (in milliseconds) that the input timer
remains on before turning off.

Off Time

Enter the period of time (in milliseconds) that the input timer
remains off before turning on.