Specifications and Dimensions

A-5

Power Dissipation

The maximum power losses Ultra5000 are shown below to help in
sizing an enclosure and any required ventilation. Typical heat losses
can run approximately one-half maximum power losses.

Catalog Number

Maximum Loss (Watts)

2098-IPD-005, 005-DN

48 + dissipative shunt

2098-IPD-010, -010-DN

48 + dissipative shunt

2098-IPD-020, -020-DN

50 + dissipative shunt

2098-IPD-030, -030DN

150 + dissipative shunt

2098-IPD-075, -075DN

300 + dissipative shunt

2098-IPD-150, -150DN

500 + dissipative shunt

2098-IPD-HV030, -030-DN

175 + dissipative shunt

2098-IPD-HV050, -050-DN

175 + dissipative shunt

2098-IPD-HV100, -100-DN

350 + dissipative shunt

2098-IPD-HV150, -150-DN

350 + dissipative shunt

2098-IPD-HV220, -220-DN

600 + dissipative shunt