2098-ipd-hv030 – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual

Page 99

Advertising
background image

Publication 2098-IN001E-EN-P — April 2002

Specifications and Dimensions

A-3

2098-IPD-HV030-xx, -HV050-xx, -HV100-xx, -HV150-xx, and

-HV220-xx

The table below lists general power specifications and requirements
for the Ultra5000 460V drives.

Specification

Description

2098-IPD-HV030

and

2098-IPD-HV030-DN

2098-IPD-HV050

and

2098-IPD-HV050-DN

2098-IPD-HV100

and

2098-IPD-HV100-DN

2098-IPD-HV150

and

2098-IPD-HV150-DN

2098-IPD-HV220

and

2098-IPD-HV220-DN

AC Input Voltage

1, 2

230-480V

rms

Three Phase

AC Input Frequency

47 - 63 Hz

Main AC Input Current

3

Nominal, 460V ac input

Maximum inrush, 460V ac input

4A

rms

6A

rms

7A

rms

6A

rms

14A

rms

6A

rms

20A

rms

6A

rms

28A

rms

6A

rms

Auxiliary AC Input Current

Nominal, 230V ac input

Nominal, 360V ac input

Nominal, 480V ac input

Maximum inrush, 230V ac input

4

Maximum inrush, 480V ac input

4

0.55A

rms

0.35A

rms

0.25A

rms

47A (0-peak)
68A (0-peak)

0.55A

rms

0.35A

rms

0.25A

rms

47A (0-peak)
68A (0-peak)

0.55A

rms

0.35A

rms

0.25A

rms

47A (0-peak)
68A (0-peak)

0.55A

rms

0.35A

rms

0.25A

rms

47A (0-peak)
68A (0-peak)

0.55A

rms

0.35A

rms

0.25A

rms

47A (0-peak)
68A (0-peak)

Continuous Output Current

7A (0-peak)

11A (0-peak)

23A (0-peak)

34A (0-peak)

47A (0-peak)

Intermittent Output Current

14A (0-peak)

22A (0-peak)

46A (0-peak)

68A (0-peak)

94A (0-peak)

Internal Shunt

Continuous power
Peak power

100W
5.3 kW

100W
5.3 kW

200W
16 kW

200W
25.6 kW

400W
32 kW

External Shunt

Minimum resistance
Continuous power
Peak power

120 Ohms
3 kW
5.3 kW

120 Ohms
5 kW
5.3 kW

40 Ohms
10 kW
16 kW

25 Ohms
15 kW
25.6 kW

20 Ohms
22 kW
32 kW

Energy Absorption Capability

230V ac input with 230V motor
230V ac input with 460V motor
460V ac input

58 Joules

517 Joules

219 Joules

58 Joules

517 Joules

219 Joules

88Joules

776Joules

329 Joules

117 Joules

1034 Joules

439 Joules

234 Joules

2069 Joules

878Joules

Continuous Power Output

230V ac input
460V ac input

1.5 kW

3.0 kW

2.5 kW

5.0 kW

5.0 kW

10 kW

7.5 kW

15 kW

11 kW

22 kW

1

Specification is for nominal voltage. The absolute limits are ±10%, or 207-528V

rms

.

2

The 2098-IPD-HVxxx-xx drives can be powered with 230-240 Vrms in order to be used in conjunction with motors designed for 230V operation. In such cases, the voltage levels used for
shunting and DC bus overvoltage limits are adjusted to be compatible with the voltage limit of the motor.

3

The 2098-HV

xxx -xx (460V) drives are limited to three contactor cycles per minute.

4

400

μs half wave sine, inrush current is processor controlled via soft start circuitry.