Publication 2098-IN001E-EN-P — April 2002

3-8

Connecting Your Ultra5000

Figure 3.6

Motor Power Cable Shield Connection (bottom of drive)

Figure 3.7

Motor Power Cable Shield Connection (front of drive)

Y-Series motors have a short pigtail cable which connects to the
motor, but is not shielded. These motor power cables have a 152.4
mm (6.0 in.) shield termination wire with a ring lug that connects to
the closest earth ground. The termination wire may be extended to
the full length of the motor pigtail if necessary, but it is best to
connect the supplied wire directly to ground without lengthening.
Refer to

Figure 3.8

for an illustration.

Figure 3.8

Y-Series Motor Power Cable Connection

V

W

Ultra5000

Motor cable jacket

Clamp screws

Shield

Clamp

Motor cable jacket

Motor cable jacket

Motor cable jacket

Shield

Ultra5000

Clamp screws

Clamp

Motor power cable

Pigtail cable

152.4 mm (6.0) Termination

Y-Series

Connectors