Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual
Page 68

Publication 2098-IN001E-EN-P — April 2002
3-8
Connecting Your Ultra5000
Figure 3.6
Motor Power Cable Shield Connection (bottom of drive)
Figure 3.7
Motor Power Cable Shield Connection (front of drive)
Y-Series motors have a short pigtail cable which connects to the
motor, but is not shielded. These motor power cables have a 152.4
mm (6.0 in.) shield termination wire with a ring lug that connects to
the closest earth ground. The termination wire may be extended to
the full length of the motor pigtail if necessary, but it is best to
connect the supplied wire directly to ground without lengthening.
Refer to
for an illustration.
Figure 3.8
Y-Series Motor Power Cable Connection
V
W
Ultra5000
Motor cable jacket
Clamp screws
Shield
Clamp
Motor cable jacket
Motor cable jacket
Motor cable jacket
Shield
Ultra5000
Clamp screws
Clamp
Motor power cable
Pigtail cable
152.4 mm (6.0) Termination
Y-Series
Connectors