Publication 2098-IN001E-EN-P — April 2002

Ultra5000 Connector Information

2-33

The following table provides a description of the auxiliary encoder
interface.

Parameter

Description

Minimum Maximum

ON State

Input Voltage

Input voltage difference between the +
input and the - input that is detected as
an ON state.

+1.0V

+7.0V

OFF State

Input Voltage

Input voltage difference between the +
input and the - input that is detected as
an OFF state.

-1.0V

-7.0V

Common Mode

Input Voltage

Potential difference between an encoder
signal and logic ground.

-7.0V

+12.0V

DC Current Draw

Current draw into the + and - input.

-5mA

5mA

Signal Frequency

Frequency of the AX or BX signal inputs.
Count frequency is 4 times this
frequency for A/B/I type inputs.

2.5 MHz

IX Pulse Width,
A/B/I Mode

Pulse width of the index input signal.
Since the index is active for a
percentage of a revolution, the speed
will determine the pulse width.

125 nS

AX / BX Phase
Error, 2.5 MHz Line
Frequency, A/B/I
Mode

Amount that the phase relationship
between the AM and BM inputs can
deviate from the nominal 90°.

-22.5°

+22.5°

AX / BX Phase
Error, 1 MHz Line
Frequency, A/B/I
Mode

Amount that the phase relationship
between the AM and BM inputs can
deviate from the nominal 90°.

-45°

+45°