Ultra5000 Connector Information

Digital Outputs

There are eight general purpose digital outputs. They are not
connected in hardware to perform a particular function. Seven digital
outputs are transistor outputs, and the drive has a single relay output
(Output 8) with normally open contacts.

The configuration of the transistor outputs is shown in

Figure 2.9

, and

the configuration of the relay output is shown in

Figure 2.10

.

Figure 2.9

Transistor Output Hardware Configuration

The following table provides a description of the transistor digital
output specifications.

IMPORTANT

There is no overload protection on the transistor
outputs. To some degree, the bipolar transistors limit
their own current output, but they have not been
designed to specifically protect against shorts to
power or ground.

Parameter Description

Minimum Maximum

ON State
Current

Current flow when the output transistor is ON

50 mA

OFF State
Current

Current flow when the output transistor is OFF

0.1 mA

ON State
Voltage

Voltage across the output transistor when ON

1.5V

OFF State
Voltage

Voltage across the output transistor when OFF

50V