2098-ipd-030-xx, -075-xx, and -150-xx, 2098-ipd-030 – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual

Page 98

Advertising
background image

Publication 2098-IN001E-EN-P — April 2002

A-2

Specifications and Dimensions

2098-IPD-030-xx, -075-xx, and -150-xx

The table below lists general power specifications and requirements
for the Ultra5000 230V drives.

Specification

Description
2098-IPD-030,

2098-IPD-030-DN

2098-IPD-075,

2098-IPD-075-DN

2098-IPD-150,

2098-IPD-150-DN

AC Input Voltage

1

100-240V

rms

Single Phase

100-240V

rms

Three Phase

AC Input Frequency

47 - 63 Hz

Main AC Input Curren

t

2

Nominal,

Maximum inrush, 230V ac input

28A

rms

50A

rms

30A

rms

50A

rms

46A

rms

68A

rms

Auxiliary AC Input Current

Nominal, 115V ac input

Nominal, 230V ac input

Maximum inrush, 115V ac input

3

Maximum inrush, 230V ac input

3

1.0A

rms

0.5A

rms

47A (0-peak)
95A (0-peak)

1.0A

rms

0.5A

rms

47A (0-peak)
95A (0-peak)

1.0A

rms

0.5A

rms

47A (0-peak)
95A (0-peak)

Continuous Output Current

15A (0-peak)

35A (0-peak)

65A (0-peak)

Intermittent Output Current

30A (0-peak)

75A (0-peak)

150A (0-peak)

Internal Shunt

Continuous power
Peak power

50W
4.5 kW

50W
10 kW

180W
18 kW

External Shunt

Minimum resistance
Continuous power
Peak power

30 Ohms
2.4 kW
6 kW

16.5 Ohms
4 kW
10 kW

9 Ohms
8 kW
19 kW

Energy Absorption Capability

115V ac input
230V ac input

203 Joules

96 Joules

321 Joules

151 Joules

563 Joules

265 Joules

Continuous Power Output

115V ac input
230V ac input

1.5 kW

3 kW

3.75 kW

7.5 kW

7.5 kW

15 kW

1

Specification is for nominal voltage. The absolute limits are ±10%, or 88-265V

rms

.

2

The 2098-030-

xx, -075-xx, and -150-xx (230V) drives are limited to two contactor cycles per minute.

3

400

μs half wave sine, inrush current is processor controlled via soft start circuitry.

Advertising