Publication 2098-IN001E-EN-P — April 2002

Ultra5000 Connector Information

2-21

OFF State Voltage,
Active Low
Configuration

Voltage applied to the input, with
respect to IOPWR, to guarantee an OFF
state.

-3.0V

1.0V

Propagation
Delay,

High Speed Inputs

Signal propagation delay from the high
speed digital input to the firmware
accessible registers, active high or
active low, turning ON or turning OFF.

0.5 mS

Propagation
Delay,

Low Speed Inputs

Signal propagation delay from the low
speed digital input to the
firmware-accessible registers, active
high or active low, turning ON or turning
OFF.

100 mS

Parameter

Description (Continued)

Minimum

Maximum