300 watt active shunt ferrites, 2090 series passive shunts, With 300 watt active shunt ferrites – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual

Page 141: 2090-sr120-09, 2090-sr040-09, 2090-sr040-18, 2090-sr025-09, 2090-sr025-18, 2090-sr020-36

Advertising
background image

Publication 2098-IN001E-EN-P — April 2002

Catalog Numbers and Accessories

C-5

300 Watt Active Shunt Ferrites

Ferrites are used at both ends of the DC Bus wires for CE radiated
emissions compliance. Use the following table to select a ferrite
assembly.

2090 Series Passive Shunts

2090-Series of Passive Shunts compatible with 460V Ultra5000 drives
(i.e., -HV) are shown in the following table:

Box shaped ferrite assembly in fully
enclosed nylon case. End ports are
surrounded with flexible spring flutes to
grip a range of cable diameters from.125
to.500” (3.2 to 12.7mm).
FerriShield, Inc.

350 Fifth Avenue, Suite 7310

New York, NY 10118-7591

Mfg. Part/No.

D

E

Impedance

SS28B2034

0.250

0.120

125

Ω

SS28B2037

0.350

0.200

154

Ω

SS28B2032

0.500

0.200

230

Ω

Applicable Drives

Shunt

Catalog No.

Shunt Ratings:

Resistance

1

Peak Power @

460V

Peak Power @

230V

Power

Continuous

2098-IPD-HV030-

xx

2098-IPD-HV050-

xx

2090-SR120-09

120 – 148 Ohms

5.3 kW

1.33 kW

2

900W

2098-IPD-HV100-

xx

2090-SR040-09

40 – 51 Ohms

16.0 kW

4.0 kW

2

900W

2098-IPD-HV100-

xx

2090-SR040-18

40 – 49 Ohms

16.0 kW

4.0 kW

2

1800W

2098-IPD-HV150-

xx

2090-SR025-09

25 – 32 Ohms

25.6 kW

6.4 kW

2

900W

2098-IPD-HV150-

xx

2090-SR025-18

25 – 31 Ohms

25.6 kW

6.4 kW

2

1800W

2098-IPD-HV220-

xx

2090-SR020-36

20 – 25 Ohms

32.0 kW

8.0 kW

2

3600W

1

Tolerance = +20%, - 0%

2

Replacement of the 460V fuse with the supplied 230V fuse kit is required to convert these shunts for use with Ultra Series

HV drives operating on

230V input power.