Publication 2098-IN001E-EN-P — April 2002

2-12

Ultra5000 Connector Information

Terminal Block 1 (TB1) Locations

(2098-IPD-075-xx and -150-xx)

U (Motor)

2

V (Motor)

2

W (Motor)

2

Motor Case Ground

DC Bus+

1

DC Bus-

1

L1 (Main AC)

L2 (Main AC)

L3 (Main AC)

Safety (Earth) Ground

L1 (Aux AC)

3

L2/N (Aux AC)

3

1

Do not connect an external I/O power supply to the DC bus. The DC+ and DC- terminals
connect directly to the power bus of the drive.

2

Ensure motor power is wired with proper phasing relative to the motor terminals. On some
motors, the motor leads may be labeled R, S, and T which correspond to U, V, and W.

3 The auxiliary AC power inputs require dual element time delay (slow acting) fuses to

accommodate inrush current. Refer to the section

General Power Specifications

in

Appendix

A

for the inrush current on the auxiliary AC power input.

Shunt Terminal Block 2 (TB2) Locations

(2098-IPD-075-xx and -150-xx)

1 - Common Terminal for External or Internal Shunt

1

2 - Internal Shunt Terminal

1

3 - External Shunt Terminal

1

1

A jumper, selecting the internal shunt, is factory installed between terminals 1 and 2. Remove the jumper for
applications requiring an external shunt.

Refer to External Shunt Kits on page C-4

for information about available external shunt kits.