Wiring your ultra5000, Connecting interface cables, Wiring i/o connections – Rockwell Automation 2098-IPD-xxx Ultra5000 Intelligent Positioning Drives Installation Manual User Manual

Page 69: Wiring your ultra5000 -9

Advertising
background image

Publication 2098-IN001E-EN-P — April 2002

Connecting Your Ultra5000

3-9

Wiring Your Ultra5000

These procedures assume you have bonded and mounted your
Ultra5000 to the subpanel and that there is no power applied to the
system.

The following sections provide information and procedures on how to
wire your Ultra5000.

Connecting Interface Cables

Connect all interface cables as shown in the table below.

Wiring I/O Connections

To wire your CN1A and CN1B I/O connectors:

1. Prepare your I/O wires by stripping approximately 6 mm (0.25 in.)

of insulation from the end.

Note:

Use caution not to nick, cut, or otherwise damage strands
as you remove the insulation.

2. Using the small blade type screw driver supplied with your

Ultra5000 (part number 9111-0031) depress the spring clamp next
to the pin you’re prepared to wire and insert the wire, as shown in

Figure 3.9

.

ATTENTION

!

This product contains ESD (Electrostatic Discharge)
sensitive parts and assemblies. Follow static control
precautions when you install, test, service, or repair
this assembly.

Refer to Allen-Bradley publication

8000-4.5.2

,

Guarding Against Electrostatic Damage or any other
applicable ESD Protection Handbook.

Failure to observe this precaution may result in
damage to the equipment.

This cable:

Plugs into this connector:

28-pin, Digital I/O

CN1A

14-pin, Auxiliary encoder/analog I/O

CN1B

15-pin, Motor encoder feedback

CN2

9-pin, Main serial port

CN3A

9-pin, Auxiliary serial port

CN3B

Advertising