Specifications and Dimensions

A-7

Inputs and Outputs

The table below lists I/O specifications.

Communications

The table below lists the communication specifications for serial
communications and the optional DeviceNet interface.

Specification

Description

General Purpose
Digital Inputs

16 Optically Isolated 12-24 Volt Inputs

Inputs/Outputs -

Sinking/Sourcing
Selection

Software Selectable as a Group to be Active High, Current Sinking
or Active Low, Current Sourcing

General Purpose
Digital Outputs

7 Optically Isolated 12-24 Volt Outputs - 50 Milliamperes Maximum

General Purpose
Relay Output

1 Normally Open Relay - 30 Volts dc Maximum,

1A Maximum Current

General Purpose I/O
Response

100 µsec

High Speed Input
Response

< 1 µsec (Inputs 1 and 2)

Position Capture
Response

< 1 µsec (Input 1, Input 2, Motor Encoder Index, and Auxiliary
Encoder Index)

General Purpose
Analog Inputs

2 12-Bit Analog to Digital Converters (+/- 10V, single-ended)

General Purpose
Analog Outputs

2 12-Bit Digital to Analog Converters (+/- 10V,

+/- 2mA, single-ended)

Specification

Description

Serial:

Ports

Two RS-232/RS-422/RS-485

Baud Rates

1200, 2400, 4800, 9600, 19200, and 38400 baud

DeviceNet (option):

Power Consumption from
Network

60 mA

Data Rates

125 kps, 250 kps, and 500 kps

Node Addresses

01-63

Messaging Capabilities

Explicit, polled I/O