Publication 2098-IN001E-EN-P — April 2002

3-18

Connecting Your Ultra5000

5. Tighten each terminal screw to the appropriate torque value.

6. Gently pull on each wire to make sure it does not come out of its

terminal. Re-insert and tighten any loose wires.

7. To connect the motor power cable:

Ultra5000 Drives:

Terminal Block Torque Values:

2098-IPD-005xx, -010-xx, and -02-xx

1.25 Nm (11 lb-in.)

2098-IPD-030-xx

2098-IPD-075-xx

2098-IPD-150-xx

2.26 Nm (20 lb-in.)

2098-IPD-HVxxx-xx

1.25 Nm (11 lb-in.)

IMPORTANT

The DC bus connections should not be used for
connecting multiple drives together. Contact your
Allen-Bradley representative for further assistance if
the application may require DC power connections.

If your motor is:

Then:

F-Series, H-Series,
MP-Series, N-Series,
W-Series, or
1326AB-Bxxxx-M2L
or -S2L

1. Remove the two screws securing the cable

shield clamp on the Ultra5000 drive (refer
to figures

3.6

or

3.8

for the cable clamp

location on your Ultra5000 drive).

2. Place the cable within the clamp and

replace the screws (do not tighten).

3. Position the exposed portion of the cable

braid directly in line with the clamp.

4. Tighten the screws with a torque of 0.9-1.1

Nm (8.0-10.0 lb-in.).

5.

Continue with optional

step 8

or

step 9

.

Y-Series

1. Connect the 152.4 mm (6.0 in.) termination

wire to the closest earth ground (refer to

Figure 3.8

for pigtail location).

2. Continue with optional

step 8

or

step 9

.