7. The RT (Real Time) and ChartsPlus options will only run as ClickOnce applications
on a 64-bit operating system.
8. The .NET Framework must be installed after IIS is installed and running. If IIS is
installed after these components then you must reinstall those components.
9. If a Powermonitor on Remote I/O Device is created with a rack/group address that
does not exist, the RT device viewer may display bogus data.
10. FactoryTalk EnergyMetrix RT does not support DeviceNet communication to the
Powermonitor II.
11. If FactoryTalk EnergyMetrix is installed with a connection to a SQL server on another
machine, SQL Server 2005 or 2008 Express Edition must be installed on the
FactoryTalk EnergyMetrix server.
12. Scheduling many auto-run reports to run at the same time may cause excessive server
resource demand and cause reports to time out.
13. Reports run automatically in Excel format may not be viewed in the Web browser if
the client has Microsoft Office 97 or later installed.
The report may still be saved and opened by using Microsoft Excel.
14. To utilize roll-up server functionality, Internet Explorer WebControls 1.0 must be
installed on the server.