3

Installation

45

2. If not already installed, install Microsoft SQL Server 2005 or 2008 (NOT included in

FactoryTalk EnergyMetrix base software but 2008 is available as a bundled option).

3. Using Internet Information Services manager, verify that ASP.NET version 2.0 is

selected in the default web page properties.

If it is not, select ASP.NET version 2.0 and run IISRESET before installing the
software.

4. Insert the FactoryTalk EnergyMetrix software installation DVD into the server’s

DVD drive.

If auto-run is enabled, the installation menu will launch. If not enabled, browse to and
launch autorun.exe in the root folder of the DVD.

5. From the installation menu, install the Factory Talk Activation Manager.

6. Install RSLinx Classic Lite software version 3.60 (CPR 9 SR6).

7. Install Microsoft .NET Framework version 3.5 SP1.

8. If not already installed, install Adobe Acrobat Reader.

9. Install FactoryTalk EnergyMetrix software:

a.

Accept the license agreement and enter the serial number of the Manager software
when prompted.

b. When prompted, enter the computer name or IP address of the SQL Server (the

default is (local) for a SQL server hosted on the FactoryTalk EnergyMetrix
server).

SQL Server must be set up with mixed-mode authentication (Windows and SQL
Server). You can make this selection during initial installation or by using Enterprise
Manager and editing the server properties, security tab after installation. We
recommend that you do not use the default system administrator login (username =
‘sa’, password = “”) due to known security issues. Record the system administrator
login credentials as you will be prompted to enter them when you install
FactoryTalk EnergyMetrix software. The same SQL database login will be required
when the software is upgraded to a new version eventually.

If the SQL Server is to be hosted on another computer, download (if needed) and
install SQL Server 2005 or 2008 Express Edition on the FactoryTalk EnergyMetrix
server at this time.

The installation menu provides a link to the FactoryTalk
EnergyMetrix online Help.

This step is recommended but not required when upgrading an
existing installation.

This step is recommended but not required when upgrading an
existing installation on a 32-bit Windows Server 2003 operating
system.