Rockwell Automation 9307 FactoryTalk EnergyMetrix User Manual

Page 46

Advertising
background image

FactoryTalk EnergyMetrix Software

46

Then, enter the SQL system administrator account login credentials.

c.

Accept the remaining prompts. The installation will proceed.

During the installation, the FactoryTalk EnergyMetrix SQL database is created,
populated with stock values and updated to the current version.

d. When prompted, reboot the server to complete the installation.

5. After the server restarts, log in as an administrator, and then open the Windows

Control Panel > Administrative Tools > Computer Management > Local Users and
Groups.

a.

Select Users and right-click the ASPNET user name option.

b. Select Properties and select the Member Of tab.

c.

If Administrators does not appear in the list, then click Add, and then click
Advanced.

d. Click Find Now.

e.

Select Administrators and click OK.

f.

When finished, reset IIS (Start > Run > ‘iisreset’> OK).

7. Install activations for Manager and all purchased options by using the Factory talk

Activation Manager.

8. Launch Internet Explorer on the server.

9. Enter the server url (universal resource locator) into the Internet Explorer address

field:

http://localhost/ftenergymetrix

10. When the login screen appears, log in by using the default login credentials.

To use FactoryTalk EnergyMetrix software from a client
workstation, substitute the FactoryTalk EnergyMetrix server
name or IP address for ‘localhost’ in the url.

If any errors are displayed when you try to log in or once you have logged in, please
refer to

Troubleshooting on page 303

.

Advertising