Rockwell Automation RECOMM-DNET DeviceNet Adapter for use with DPI AC Drives User Manual
Page 102

B-10
DeviceNet Adapter for use with DPI AC Drives
Amount of time that a scanner will wait to check for data in the
adapter.
When COS (change of state) data exchange has been set up, this is
the maximum amount of time between scans. Scans will happen
sooner if data changes.
When cyclic data exchange has been set up, this interval is the fixed
time between scans. This interval is configured in the scanner.
Destination in the drive of the Peer Input. The adapter receives this
data from the network and sends it to the drive.
Important: These parameters can be changed only when Peer Inp
Enable (37) is Off.
Important: If a 32-bit Datalink or Reference is used in Peer A Input
(30), Peer B Input (31) cannot be used.
29
COS/Cyc Interval
Range:
0 to 655.35 seconds
Default:
0 seconds
Type:
Read Only
Reset Required: N/A
30
31
Peer A Input
Peer B Input
Range:
0 = Off
1 = Cmd/Ref
2 = DL A Input
3 = DL B Input
4 = DL C Input
5 = DL D Input
Default:
0 = Off
Type:
Read/Write
Reset Required: No