DeviceNet Objects

C-27

The PLC data in this example is for a Set_Attributes_Scattered of
SP600 parameters; Accel Time 1 (140), Decel Time 1 (142), and
Jog Speed (100) to a device at node address 1.

Request Data for Set_Attributes_Scattered

Request

Response

Word 0

TXID

Command

TXID

Status

12

Parameter Number

Parameter Number

13

Parameter Value LSW

Pad Word or Error Code

14

Parameter Value MSW

Pad Word

15

Parameter Number

Parameter Number

16

Parameter Value LSW

Pad Word or Error Code

17

Parameter Value MSW

Pad Word

18

Parameter Number

Parameter Number

19

Parameter Value LSW

Pad Word or Error Code

20

Parameter Value MSW

Pad Word

21

Parameter Number

Parameter Number

22

Parameter Value LSW

Pad Word or Error Code

23

Parameter Value MSW

Pad Word

24

Parameter Number

Parameter Number

25

Parameter Value LSW

Pad Word or Error Code

26

Parameter Value MSW

Pad Word

27

Parameter Number

Not Used

28

Parameter Value LSW

Not Used

29

Parameter Value MSW

Not Used

30

Not Used

Not Used

Word 31

Not Used

Not Used

Address

Value

(hex)

Description

Refer to . . .

N30:0

0101

TXID = 01, Command = 01 (execute)

Section 7.3

N30:1

0018

Port = 00, Size = 24 bytes (18 hex)

Section 7.3

N30:2

4C01

Service = 4C (Set_Attributes_Scattered)

Page C-24

Address = 01 (Node Address)

Section 7.3

N30:3

0093

Class = 93 (DPI Parameter Object)

Page C-19

N30:4

0000

Instance = Class Attributes (drive)

Page C-19