DeviceNet Objects

C-5

Services

12

Get/Set

Watchdog
Action

USINT

0 = Transition to timed out
1 = Auto delete
2 = Auto reset

13

Get

Produced
Path Length

UINT

Number of bytes of data in the
produced connection path

14

Get

Produced
Connection
Path

ARRAY
of
UINT

Byte stream which defines
Application objects whose data is
to be produced by this Connection
object

15

Get

Consumed
Path Length

UINT

Number of bytes of data in the
consumed connection path

16

Get

Consumed
Connection
Path

ARRAY
of USINT

Byte stream which defines
Application objects whose data is
to be consumed by this Connection
object

Attribute

ID

Access

Rule

Name

Data

Type

Description

Service

Code

Implemented for:

Service Name

Class

Instance