C-6
DeviceNet Adapter for use with DPI AC Drives
C.3 Register Object
Class Code
Instances
Class Attributes
Not supported.
Hexadecimal
Decimal
0x07
7
Instance
Description
1
All polled data being read from the DPI device (read-only)
2
All polled data written to the DPI device (read/write)
3
Logic Status and Feedback data (read-only)
4
Logic Command and Reference data (read/write)
5
Datalink A (input data from device to scanner) (read only)
6
Datalink A (output data from scanner to device) (read/write)
7
Datalink B (input data from device to scanner) (read only)
8
Datalink B (output data from scanner to device) (read/write)
9
Datalink C (input data from device to scanner) (read only)
10
Datalink C (output data from scanner to device) (read/write)
11
Datalink D (input data from device to scanner) (read only)
12
Datalink D (output data from scanner to device) (read/write)
13
Logic Status and Feedback Data (read-only)
14
Mask
1
(read/write)
1
The mask command word is set to the value of the first word of the data
where there are ones in the second word of the data. Command = (word
1 and not word 2) or (word 1 and word 2). This only controls specified bits
in the Logic Command data to the DPI product and does not change the
Reference value.