bottleneckMon

2

bottleneckMon

Monitors and reports latency and congestion bottlenecks on F_Ports and E_Ports.

SYNOPSIS

bottleneckmon --enable [-cthresh congestion_threshold]
[-lthresh latency_threshold] [-time seconds]
[-qtime seconds] [-alert | -alert=congestion |
-alert=latency | -noalert]
[-lsubsectimethresh time_threshold]
[-lsubsecsevthresh severity_threshold]

bottleneckmon --disable

bottleneckmon --config [-cthresh congestion_threshold]
[-lthresh latency_threshold][-time seconds]
[-qtime seconds] [-alert | -alert=congestion |
-alert=latency | -noalert]
[-lsubsectimethresh time_threshold]
[-lsubsecsevthresh severity_threshold]
[[slot/]port_list]

bottleneckmon --configclear [slot/]port_list

bottleneckmon --exclude [slot/]port_list

bottleneckmon --include [slot/]port_list

bottleneckmon --show [-interval seconds] [-span seconds]
[-refresh][-congestion | -latency] [[slot/]port | '*']

bottleneckmon --status

bottleneckmon --cfgcredittools -intport -recover
[off | onLrOnly | onLrThresh] [-lrthresh threshold]
-fault [edgeblade | coreblade | edgecoreblade]

bottleneckmon --cfgcredittools -intport -check slot/blade_port,VC

bottleneckmon --linkreset slot/blade_port

bottleneckmon --showcredittools

bottleneckmon --help

DESCRIPTION

Use this command to (1) detect latency and congestion bottlenecks on F[L]_Ports and E_Ports and (2) to
manage credit recovery on backend ports. Bottleneck detection and credit recovery are two independent
functions; enabling credit recovery has no impact on bottleneck detection and vice versa.

Bottleneck Detection

For bottleneck detection, this command provides the following management functions:

Enabling or disabling bottleneck detection on a switch and optionally configuring thresholds and alert
parameters.

Changing alert parameters on specified ports after you have enabled the feature on the switch.