Dell POWEREDGE M1000E User Manual

Page 531

Advertising
background image

Fabric OS Command Reference

503

53-1002746-01

lfCfg

2

Port

Number of the logical LISL port.

remote-domain

Domain ID of the base switch in the remote chassis.

Name

Switch name.

State

Port state: Online or Offline.

Associated physical ports

Physical ports associated with the LISL ports.

When lfCfg is issued within a logical switch context, only the configuration regarding that switch and the
fabrics reachable from that switch is displayed. When the command is issued in a chassis context the
information for all chassis in the base fabric reachable from the current chassis is displayed. Executing
chassis-level commands requires chassis permissions. Refer to the userConfig command for
information on setting chassis user permissions.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

This command is supported only on hardware platforms that are Virtual Fabric-aware and run Fabric OS
v6.2.0 or later. Refer to the Fabric OS Administrator's Guide for specific hardware support.

You cannot use the portEnable command on logical ports. Use lfcfg with the --lislenable option to
re-enable disabled LISL ports on a logical switch.

OPERANDS

This command has the following operands:

--show -cfg

Displays information for the fabric ID set by the context in all chassis reachable
from the base fabric.

--showall -cfg

Displays information for all fabrics in all chassis reachable from the chassis
context in which the command is executed. This option requires chassis
permissions.

--show -lisl

Displays status information about the LISLs in the logical switch set by the
context.

--showall -lisl

Displays status information of all LISLs in the chassis. This option requires
chassis permissions.

-v

Displays, in addition to the LISLs, the physical ports on the base switch that are
associated with the LISL ports. This operand is optional with the -lisl option.

--show -xisl [slot/]port

Displays the XISL and the LISLs associated with it for the specified XISL port. For
each LISL port, the output displays the FID, LISL State (online/offline) and the
local and remote logical switch WWNs. This command must be executed from the
base switch.

--showall -lisl

Displays the XISL connections between two base switches for all XISL ports. This
command must be executed from the base switch.

Advertising