Dell POWEREDGE M1000E User Manual

Page 121

Advertising
background image

Fabric OS Command Reference

93

53-1002746-01

bpPortLoopbackTest

2

8

Runs test at 8 Gbps (Default for Condor2).

16

Runs test at 16 Gbps (Condor3 only).

-bpports itemlist

Specifies a list of blade ports to test. By default all valid blade ports in the specified
blade are tested. On the Brocade Encryption platforms, ports 80-103 are the only
valid ports, because these are the only blade ports with access to the Vader chip.
Refer to the itemList help page for further information on the itemlist parameter.

DIAGNOSTICS

When it detects failures, the test may report one or more of the following error messages. If errors
persist, contact Technical Support.

DATA

Data received does not match the data sent.

ERRSTAT

Errors were found in the ASIC statistics.

INIT

Port failed to initialize.

PORTDIED

A previously initialized port went to an un-initialized state.

STATS

Errors were found in the ASIC statistics.

TIMEOUT

Did not receive a frame in the given timeout period.

XMIT

Frame transmission failure.

EXAMPLES

To run the test on blade ports 80-90 with one frame:

switch:admin> bpportloopbacktest -bpports 80-90 -nframes 1
Running bpportloopbacktest ..............
Ram Init
Ob1 portloopbacktest on ports 80-90 lbMode 7 speed 4
Info: Vader port 0 recovering Rx Fifo
Info: Vader port 1 recovering Rx Fifo
Info: Vader port 2 recovering Rx Fifo
Info: Vader port 3 recovering Rx Fifo
Info: Vader port 4 recovering Rx Fifo
Info: Vader port 5 recovering Rx Fifo
Ob1 portloopbacktest on ports 80-90 PASSED
Test Complete: bpportloopbacktest Pass 1 of 1
Duration 0 hr, 0 min & 24 sec (0:0:24:599).
Cleaning up after test.......
passed.

SEE ALSO

itemList

,

portLoopbackTest

Advertising