Dell POWEREDGE M1000E User Manual

Page 824

Advertising
background image

796

Fabric OS Command Reference

53-1002746-01

portShow

2

To display the current state of a port with encryption enabled:

switch:admin> portshow 10/44
portIndex: 348
portName: slot10port44
portHealth: No Fabric Watch License

Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x10000103 PRESENT ACTIVE E_PORT T_PORT\
T_MASTER G_PORT U_PORT ENCRYPT LOGIN
LocalSwcFlags: 0x0
portType: 24.0
portState: 1 Online
Protocol: FC
portPhys: 6 In_Sync portScn: 1 Online Trunk master port
port generation number: 44
state transition count: 12

To display the state of a VE_Port on a chassis with an FX8-24 blade:

switch:admin> portshow 7/12
portIndex: 140
portName: slot7port12
portHealth: No Fabric Watch License

Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x490b PRESENT ACTIVE VIRTUAL E_PORT \
G_PORT U_PORT LOGICAL_ONLINE LOGIN LED
portType: 12.0
portState: 1 Online
Protocol: FC
portPhys: 255 N/A portScn: 16 E_Port
port generation number: 1048
state transition count: 26

portId: 018c00
portIfId: 43720806
portWwn: 20:8c:00:05:1e:7a:7a:00
portWwn of device(s) connected:

Distance: normal

To display port status for a GbE port on a Brocade 7800:

switch:admin> portshow ge2
Eth Mac Address: 00.05.1e.54.b1.17
Port State: 1 Online
Port Phys: 6 In_Sync
Port Flags: 0x4003 PRESENT ACTIVE LED
Port Speed: 1G