Dell POWEREDGE M1000E User Manual

Page 976

Advertising
background image

948

Fabric OS Command Reference

53-1002746-01

sfpShow

2

Length 50u: 5 (units 10 meters)
Length 62.5u:3 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: BROCADE
Vendor OUI: 00:05:21
Vendor PN: 57-1000046-01
Vendor Rev: A
Wavelength: 850 (units nm)
Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: UYA109301009212
Date Code: 090723
DD Type: 0x68
Enh Options: 0xf0
Status/Ctrl: 0x80
Alarm flags[0,1] = 0x0, 0x0
Warn Flags[0,1] = 0x0, 0x0
Alarm Warn
low high low high
Temperature:30 Centigrade -15 90 -10 85
Current: 5.648 mAmps 2.000 8.500 2.000 8.500
Voltage: 3300.0 mVolts 2800.0 3800.0 2970.0 3630.0
RX Power:-2.5 dBm (565.9 uW) 0.0uW 6550.0uW 49.0uW 1100.0uW
TX Power:-2.6 dBm (551.6 uW) 50.0uW 800.0uW 100.0uW 700.0uW

State transitions: 1
Last poll time: 02-03-2012 UTC Fri 07:36:05

To display detailed information for GbE port 0 on a Brocade 7800 extension switch:

switch:admin> sfpshow ge0
Identifier: 3 SFP
Connector: 0
Transceiver: 0000000008000000 id
Encoding: 1 8B10B
Baud Rate: 13 (units 100 megabaud)
Length 9u: 0 (units km)
Length 9u: 0 (units 100 meters)
Length 50u: 0 (units 10 meters)
Length 62.5u:0 (units 10 meters)
Length Cu: 100 (units 1 meter)
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000042-01
Vendor Rev: A
Wavelength: 0 (units nm)
Options: 0010 Tx_Disable
BR Max: 0
BR Min: 0
Serial No: CZA109302000053
Date Code: 090504
DD Type: 0x0
Enh Options: 0x0

SEE ALSO

fwFruCfg

,

switchShow

,

thMonitor

Advertising