Chassisshow – Dell POWEREDGE M1000E User Manual

Page 156

Advertising
background image

128

Fabric OS Command Reference

53-1002746-01

chassisShow

2

chassisShow

Displays all field replaceable units (FRUs).

SYNOPSIS

chassisshow

DESCRIPTION

Use this command to display the Field Replaceable Unit (FR) header content for each object in the
chassis and chassis backplane version. This command displays the following information:

1.

The chassis family, for example, DCX 8510.

2.

The backplane version number, in hexadecimal: Chassis Backplane Revision: xx

3.

The first line of each record contains the object ID. If the FRU is part of an assembly, a brief
description is displayed in parentheses.

a.

Object type: CHASSIS, FAN, POWER SUPPLY, SW BLADE (switch), CP BLADE (control
processor), WWN (world wide name), or UNKNOWN.

b.

Object number: Slot nn (for blades), Unit nn (for everything else).

4.

FRU header version number: Header Version: x

5.

Displays the maximum allowed power consumption for a given hardware component: positive for
power supplies and negative for power consumers. The combined total maximum allowed power
consumption for the entire chassis is shown in the output of the slotShow -p command. Power
Consume Factor: -xxx

6.

Displays the real-time power consumption for each FRU that supports real-time power
measurement. Only 16Gb blades currently support real time measurement of power being
consumed by these blades. When the capability is not supported for a FRU, the line is suppressed.
Power Usage (Watts):

7.

Factory part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx

8.

Factory serial number (up to 12 characters): Factory Serial Num:xxxxxxxxxx

9.

FRU manufacture date: Manufacture: Day: dd Month: mm Year: yyyy

10. Date of the last FRU header update: Update: Day: dd Month: mm Year: yyyy

11. Cumulative number of days the FRU has been powered on: Time Alive: dddd days

12. Time elapsed, in days, since the FRU was last powered on: Time Awake: dddd days

13. Externally supplied ID (up to 10 characters): ID: xxxxxxxxxx

14. Externally supplied part number (up to 20 characters): Part Num: xxxxxxxxxxxxxxxxxxxx

15. Externally supplied serial number (up to 20 characters): Serial Num: xxxxxxxxxxxxxxxxxxx

16. Externally supplied revision number (up to 4 characters): Revision Num: xxxx

The output of this command depends on the platforms on which it is executed. On some platforms, for
certain FRU types, a few items may not be available. In these cases, the lines are suppressed. Possibly
affected lines are 1, 3 through 7, 9, and 11 through 14. In addition, for lines 11 through 14, if there is no
data set, these lines are suppressed.

Advertising