Dell POWEREDGE M1000E User Manual

Page 643

Advertising
background image

Fabric OS Command Reference

615

53-1002746-01

perfTTmon

2

Because of a hardware limitation on Brocade devices, the following types of monitors cannot coexist on
the same ASIC chip:

If an end-to-end monitor is installed on a port in a given ASIC, you cannot install an ingress or
egress Top Talker monitor on another port on the same ASIC.

If an ingress Top Talker monitor is installed on a port in a given ASIC, you cannot install an egress
Top Talker monitor or an end-to-end monitor on another port of the same ASIC.

If an egress Top Talker monitor is installed on a port in a given ASIC, you cannot install an ingress
Top Talker monitor or an end-to-end monitor on another port of the same ASIC.

You can use the -force option to override these limitations and install incompatible monitors on ports of
the same ASIC. However, if you choose to do so, be aware that the statistics will not be accurate.

NOTES

This command requires an Advanced Performance Monitor license.

Top Talkers are incompatible with Frame Redirection, and therefore this feature is not supported on the
Brocade Encryption switch for encrypted data traffic.

Top Talkers are not supported on embedded platforms.

Top Talkers are not supported on FCoE ports or ports configured as mirror ports. Top Talkers are not
supported on VE_Ports, EX_Ports, VEX_Ports.

You cannot install a Top Talker and an End-to-End Monitor on the same port. Brocade recommends
against installing a Top Talkers and an End-to-End Monitor on the ports belonging to the same ASIC chip.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following operands:

slot

For bladed systems only, specifies the slot number of the port on which to
configure Top Talkers, followed by a slash (/).

port

Specifies the number of the port on which the Top Talker is to be configured,
relative to its slot for bladed systems. Use switchShow for a list of valid ports.

On 8Gb (Condor 2-based) platforms, port-based Top Talkers are supported only
on F_Ports. On 16Gb (Condor 3-based) platforms, port-based Top Talkers are
supported on both F_Ports and E_Ports.

Port-level Top Talker commands:

--add

Installs the Top Talker monitor on a specified F_Port or E_Port.

egress | ingress

Used with the --add option to specify the direction in which the traffic is monitored
as incoming or outgoing. This operand is required.

-force

Overrides a hardware limitation that does not allow incompatible monitors to
coexist on the same ASIC chip.

--show

Displays the top talking flows on a specified port.

number of top talking flows

Specifies "n" top talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and a
warning message. This operand is optional; if omitted, the command displays the
top 8 flows.

Advertising