Fdmicacheshow – Dell POWEREDGE M1000E User Manual

Page 381

Advertising
background image

Fabric OS Command Reference

353

53-1002746-01

fdmiCacheShow

2

fdmiCacheShow

Displays abbreviated remote FDMI device information, according to remote domain ID.

SYNOPSIS

fdmicacheshow

DESCRIPTION

Use this command to display FDMI cache information for remote domains only.

The state of each remote domain, identified by its domain ID, is shown to be unknown, known,
unsupported, or error.

The revision of the switch also displays, followed by the world wide name of the switch.

For HBAs, only the HBA identifiers and registered port lists are displayed. No detailed HBA attributes are
displayed. For registered ports, only port identifier and corresponding HBA are shown; no detailed port
attributes are displayed.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

None

EXAMPLES

To display the FDMI cache:

switch:admin> fdmicacheshow
Switch entry for domain 3
state: known
version: v310
wwn: 10:00:00:60:69:90:03:c7

HBAs:
10:00:00:00:c9:25:9b:96

Ports: 1
10:00:00:00:c9:25:9b:96

Total count of devices on the switch is 1

SEE ALSO

fdmiShow

Advertising