Fabric OS Command Reference

239

53-1002746-01

diagShow

2

diagShow

Displays diagnostics status.

SYNOPSIS

diagshow
[--slot number]
[-uports itemlist]
[-bports itemlist]
[-use_bports value]

DESCRIPTION

Use this command to display the diagnostics status for the specified list of blade or user ports.

NOTES

On 10 Gbps and 16 Gbps (Condor3-based) platforms, the following output fields display invalid values,
unless diagShow is executed while the spinFab or the portTest tests are running: "Speed", "FrTX",
"FrRX", "LLI Errs", "Loopback", "Total Diag Frames Tx" and "Total Diag Frames Rx".

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following optional operands:

--slot number

Specify which slot to operate on. If this option is not specified, the default slot 0 is
used. The default slot is designed to operate on fixed-port-count products. By
default, this command displays information for all user ports in the system.

-uports itemlist

Specify a list of user ports.

-bports itemlist

Specify a list of blade ports.

-use_bports value

If this value is nonzero, this command displays the diagnostics status for the blade
ports specified in -use_bports; otherwise, the command displays information for
the user ports specified in -uports. The default value is 0.

EXAMPLES

To display diagnostic status on a switch blade:

switch:admin> diagshow
Diagnostics Status: Fri Feb 08 15:25:24 2002
Slot: 1 UPORTS
Port BPort Diag Active Speed ......
0 15 OK UP 2G Auto ......
1 14 OK UP 2G Auto ......
2 13 OK UP 2G Auto ......
3 12 OK UP 2G Auto ......
4 31 OK UP 2G Auto ......
5 30 OK UP 2G Auto ......
6 29 OK UP 2G Auto ......
7 28 OK UP 2G Auto ......
8 47 OK UP 2G Auto ......
(output truncated)