Dell POWEREDGE M1000E User Manual

Page 739

Advertising
background image

Fabric OS Command Reference

711

53-1002746-01

portCfgShow

2

When portCfgShow is issued for a single FCoE port, only the following fields are displayed: Area
Number
, Speed Level, AL_PA Offset, RSCN Suppressed, and NPIV PP Limit. If the command is
issued without operands on a DCX with one or more FCOE10-24 blades, the port parameters that are
not valid on the FCoE ports are marked with a dash (-). Refer to the example section for an illustration.

You can identify a single port to be displayed by its port number or by its port index number. Port ranges
are supported with index numbers or by specifying a slot or a slot range. Use switchShow for a listing of
valid ports, slots, and port index numbers. When used without operands, this command displays all
persistently disabled ports on the switch.

Specifying multiple ports with the index (-i) or slot (-s) option is supported only if PortSwap is disabled.
They are not supported on GbE ports and configured F_Port trunks. Use the -i option without a port index
argument to display the portSwap status, or alternately use portSwapShow.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

The Fabric OS port configuration commands are not supported on FCoE ports.

OPERANDS

This command has the following operands:

slot

For bladed systems only, specifies the slot number of the port to be configured,
followed by a slash (/).

port

Specifies the number of the port to be displayed, relative to its slot for bladed
systems. Use switchShow for a listing of valid port numbers.

-i index1[-index2]

Specifies a port or a range of ports identified by port index numbers. You can
specify multiple index ranges separated by a space, for example, -i 33-38 40-60.

-f

Ignores nonexisting ports. This operand is valid only with the -i option.

-slot slot1[-slot2]

Specifies a slot or a range of slots. You can specify multiple slot ranges separated
by a space, for example,-s 1-3 5-7.

ge_port

Specifies the number of the GbE Port to be displayed. The GbE ports are
numbered ge0 - ge9 on the Brocade FX8-24 blade and ge0 - ge5 on the Brocade
7800 switch. The 10GbE ports on the Brocade FX8-24 blade are numbered xge0
and xge1. Use the switchShow command for a list of valid ports.

Use portCfgShow with a GbE port or with one of the optional arguments to display specific FCIP-related
parameters.

Displays supported on the Brocade 7800/FX8-24 platforms

When issued on the Brocade 7800/FX8-24, tunnels and parameters not applicable to these platforms
are not displayed. Use the portShow command to display FCIP tunnel and circuit parameters on the
Brocade 7800/FX8-24.

ipif

Displays the IP interface for both ports of the tunnel. IPv6 addresses are
supported.

iproute

Displays the IP route on the specified GbE port. IPv6 addresses are supported.

arp

Displays the address resolution protocol (ARP) table.

Advertising