Sensorshow – Dell POWEREDGE M1000E User Manual

Page 964

Advertising
background image

936

Fabric OS Command Reference

53-1002746-01

sensorShow

2

sensorShow

Displays sensor readings.

SYNOPSIS

sensorshow

DESCRIPTION

Use this command to display the current temperature, fan, and power supply status and readings from
sensors located on the switch. The actual location of the sensors varies, depending on the switch type.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

None

EXAMPLES

To view all sensor values:

switch:admin> sensorshow
sensor 1: (Temperature) is Ok, value is 39 C
sensor 2: (Temperature) is Absent
sensor 3: (Temperature) is Absent
sensor 4: (Temperature) is Absent
sensor 5: (Temperature) is Ok, value is 26 C
sensor 6: (Temperature) is Ok, value is 27 C
sensor 7: (Fan ) is Ok, speed is 2537 RPM
sensor 8: (Fan ) is Ok, speed is 2537 RPM
sensor 9: (Fan ) is Ok, speed is 2556 RPM
sensor 10: (Power Supply ) is Ok
sensor 11: (Power Supply ) is Absent
sensor 12: (Power Supply ) is Ok
sensor 13: (Power Supply ) is Absent

SEE ALSO

fanShow

,

tempShow

Advertising