KEYENCE KV Series User Manual
Page 121

Chapter 3 Simulator
2-97
1
3
3. Click the [Write Current Value] button or the [Write Preset Value] button.
•
The current value or preset value is changed.
Set items and available contents/values
Note 1: The bit length setting has priority over the radix setting. (For example, if the
bit length is changed to "1" when the bit length was set to "16" and the radix was set
to "decimal", the radix is automatically changed to "binary".)
Note 2: Each of the 32 bits and 16 bits can be registered from an appropriate
position only.
Note 3: When the bit length is "32", the lower 16 bits are assigned to a smaller
device number, and the upper 16 bits are assigned to a larger device number.
■ To cancel the settings
Click the [Cancel] button.
■ To return the timer/counter setting to the default value
Click the [Reset] button. (This button is only displayed when a timer/counter is set.)
■ Shortcut key
The operation of changing the numbering system is assigned to shortcut key
[Ctrl]+[E]. Decimal (#) and hexadecimal ($) are switched each time the [Ctrl]+[E]
keys are pressed.
Available values
Item
Contents
Ladder
Monitor all/registration monitor
monitor
Type
Select the device
—
Relay, timer, counter, counter compara-
type.
tor, high-speed counter, data memory,
temporary data memory, trimmer No.
No.
Enter the device
—
Available numbers vary depending
No.
on the device.
Attribute Bit
Select the data
—
1
*1
, 16, 32
*2
bit length.
*1: "1" is available in relay exclusively.
*2: "32" is available in relay, data
memory, temporary memory and
trimmer number only.
Radix Select the device
Decimal, Binary*1, octal, decimal, - decimal*2,
current/preset value hexade-
hexadecimal
display method.
cimal
*1: "2" is not available when the bit length is set
to "32".
*2: Binary with sign (two’s complement)
*
The radix is fixed to "2" when the bit length is
set to "1".
*
Change of the radix is reflected on the entire
window.
*
When the radix is changed, the current value is
cleared.
Com-
Select the type
Comment 1, Comment 2, Comment 3 or None
ment
of comment
displayed.
Current value
Enter the current
A value of up to 17 digits is available.
value.
Preset value
Enter the preset
The preset value can be entered only for timers/
value.
counters.
A value of up to 7 digits can be entered.
KVSKA Chap 03.P65
08.3.11, 11:29 AM
97