5 stop/reset and device all clear, Stopping/pausing the operations, Reset – KEYENCE KV Series User Manual

Page 132: Device all clear

Advertising
background image

Chapter 3 Simulator

2-108

3

3.3.5

Stop/reset and device all clear

To stop/reset execution of scans or steps, or to clear all the devices, perform the
following procedure.

Stopping/pausing the operations

Execute

➔ Stop (Shift + F5)

➔ Pause (F4)

Operations can be stopped or paused.

Select "Stop" or "Pause" from the "Execute" menu, or click the

or

button.

•

When "Stop" is specified, all types of operations are stopped and the output Y is
cleared.

•

When "Pause" is specified, all types of operations are temporarily stopped.

Note: When operations are stopped, execution of a step in the reverse direction is
not available. To execute a step in the reverse direction after stopping operations,
you must execute the steps again. When operations are paused, execution of a step
in the reverse direction can be performed.

Reset

Execute

➔ Reset (F10)

The current value can be returned to the default value.

Select "Reset" from the "Execute" menu, or click the

button.

•

When this procedure is performed during operation, the operation is stopped.

•

The system is processed as if the power of the PLC is turned off, and is then
turned on again.

Device all clear

Execute

➔ Device All Clear ➔ DM All Clear

➔ Latching Relay All Clear

➔ Counter All Clear

By the device all clear function, the current value of some devices can be initialized.
The following three initialization methods are available.

Clearing all data memory

Execute

➔ Device All Clear ➔ DM All Clear

Clearing all latching relays

Execute

➔ Device All Clear ➔ Latching Relay All Clear

Clearing all counters

Execute

➔ Device All Clear ➔ Counter All Clear

•

When device all clear is performed during operation, the operation is stopped.

KVSKA Chap 03.P65

08.3.11, 11:29 AM

108