3 registration monitor window, 4 registering devices – KEYENCE KV Series User Manual

Page 146

Advertising
background image

Chapter 3 Simulator

2-122

3

3.5.3

Registration monitor window

On the registration monitor window, timing charts and comments are displayed
along with the device data, current values and preset values.

When many devices are registered, it is recommended that you open two or
more windows for easier viewing.

The cursor can be moved using the LEFT/RIGHT/UP/DOWN keys.

While the simulator is running, the current values are changed continuously
according to the operation speed.

Displaying comments or timing charts
Whether timing charts or comments are to be displayed can be set for each device
using "Comment" on the dialog bar.

No: Timing charts are displayed.
Comment 1, Comment 2 or Comment 3: Comments are displayed (along with the
preset value in the case of a timer/counter).

3.5.4

Registering devices

To perform a simulation using the registration monitor, a device must be registered.
Two methods are available to register a device.

Registering a device by dragging it from the ladder monitor window

➮ The registration procedure is the same as step 2 and onward in the procedure described for the

monitor all. Refer to page 2-114.

Registering a device by specifying it using the dialog bar

➮ The registration procedure is the same as that described for the monitor all. Refer to page 2-115.

Device No.

Bit device status

Vertical cursor

Current value

Preset value

Comment

Timing chart

Cursor

KVSKA Chap 03.P65

08.3.11, 11:29 AM

122

Advertising