Chapter 3 Simulator

2-122

3

3.5.3

Registration monitor window

On the registration monitor window, timing charts and comments are displayed
along with the device data, current values and preset values.

•

When many devices are registered, it is recommended that you open two or
more windows for easier viewing.

•

The cursor can be moved using the LEFT/RIGHT/UP/DOWN keys.

•

While the simulator is running, the current values are changed continuously
according to the operation speed.

■ Displaying comments or timing charts
Whether timing charts or comments are to be displayed can be set for each device
using "Comment" on the dialog bar.

No: Timing charts are displayed.
Comment 1, Comment 2 or Comment 3: Comments are displayed (along with the
preset value in the case of a timer/counter).

3.5.4

Registering devices

To perform a simulation using the registration monitor, a device must be registered.
Two methods are available to register a device.

Registering a device by dragging it from the ladder monitor window

➮ The registration procedure is the same as step 2 and onward in the procedure described for the

monitor all. Refer to page 2-114.

Registering a device by specifying it using the dialog bar

➮ The registration procedure is the same as that described for the monitor all. Refer to page 2-115.

Device No.

Bit device status

Vertical cursor

Current value

Preset value

Comment

Timing chart

Cursor

KVSKA Chap 03.P65

08.3.11, 11:29 AM

122